We stick with the theory of quality first, company first, steady improvement and innovation to satisfy the customers for the management and zero defect, zero complaints as the quality objective. To perfect our provider, we deliver the items together with the fantastic good quality at the reasonable value for
Cross Flow Membrane
, Hollow Fibre Filtration
, Water Filter System
, Good quality and competitive prices make our products enjoy a high reputation all over the word.
Lowest Price for Water Treatment Filter -
UF Membrane Module 9 inch PVDF Ultrafiltration Membrane Module UFf2880 Replacing Project – Bangmo Detail:
Applications
Drinking treatment of tap water, surface water, well water and river water.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service?conditions of different water sources:
Ingredient |
Effect |
SS, Particles?> 1μm |
Removal Rate?≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
>?4 log |
Turbidity |
< 1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 25NTU.
Product Parameters

Technical Parameters
Filtering?Type |
Outside-in |
Membrane?Material |
Modified?PVDF |
MWCO |
200K Dalton |
Membrane?Area |
77m2 |
Membrane?ID/OD |
0.8mm/1.3mm |
Dimensions |
Φ225mm*2360mm |
Connector?Size |
DN50 Clamping; Air?Inlet?– 10mm?air?pipe |
Application Data
Pure?Water?Flux |
11,000L/H?(0.15MPa, 25C) |
Designed?Flux |
40-120L/m2.hr?(0.15MPa, 25C) |
Suggested?Working?Pressure |
≤ 0.2MPa |
Maximum?Transmembrane?Pressure |
0.15MPa |
Maximum?Backwashing?Pressure |
0.15MPa |
Air?Washing?Volume |
0.1-0.15N m3/m2 .hr |
Air?Washing?Pressure |
≤ 0.1MPa |
Maximum?Working?Temperature |
45C |
PH?Range |
Working: 4-10; Washing: 2-12 |
Operating?Mode |
Cross?Flow?or Dead End |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused?by large particles in raw water.
Turbidity |
≤ 25NTU |
Oil?&?Grease |
≤?2mg/L |
SS |
≤ 20mg/L |
Total?Iron |
≤?1mg/L |
Continuous?Residual?Chlorine |
≤?5ppm |
COD |
Suggested?≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Backwashing?Flow?Rate |
100-150L/m2.hr |
Backwashing?Frequency |
Every?30-60min. |
Backwashing?Duration |
30-60s |
CEB?Frequency |
0-4?times per day |
CEB?Duration |
5-10min. |
CIP?Frequency |
Every 1-3 months |
Washing?Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic?Pollution?Washing |
0.2%?Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic?Pollution?Washing |
1-2% Citric?Acid/0.2% Hydrochloric?Acid |
Component Material
Component |
Material |
Membrane |
Modified?PVDF |
Sealing |
Epoxy?Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
Dedicated to strict quality management and thoughtful client services, our experienced staff customers are generally available to discuss your demands and guarantee full client pleasure for
Lowest Price for Water Treatment Filter -
UF Membrane Module 9 inch PVDF Ultrafiltration Membrane Module UFf2880 Replacing Project – Bangmo , The product will supply to all over the world, such as: Nicaragua
, Costa rica
, Cologne
, Since always, we adhering to the open and fair, share to get, the pursuit of excellence, and creation of valuevalues, adhere to theintegrity and efficient, trade-oriented, excellent way , excellent valve business philosophy. Together with our all over the world have branches and partners to develop new business areas, maximum common values. We sincerely welcome and together we share in global resources, opening up new career together with the chapter.