Factory supplied Membrane Filtration Wastewater Treatment -
UF Membrane Module 9 inch PVDF Ultrafiltration Membrane Module UFf2880 Replacing Project – Bangmo Detail:
Applications
Drinking treatment of tap water, surface water, well water and river water.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service?conditions of different water sources:
Ingredient |
Effect |
SS, Particles?> 1μm |
Removal Rate?≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
>?4 log |
Turbidity |
< 1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 25NTU.
Product Parameters

Technical Parameters
Filtering?Type |
Outside-in |
Membrane?Material |
Modified?PVDF |
MWCO |
200K Dalton |
Membrane?Area |
77m2 |
Membrane?ID/OD |
0.8mm/1.3mm |
Dimensions |
Φ225mm*2360mm |
Connector?Size |
DN50 Clamping; Air?Inlet?– 10mm?air?pipe |
Application Data
Pure?Water?Flux |
11,000L/H?(0.15MPa, 25C) |
Designed?Flux |
40-120L/m2.hr?(0.15MPa, 25C) |
Suggested?Working?Pressure |
≤ 0.2MPa |
Maximum?Transmembrane?Pressure |
0.15MPa |
Maximum?Backwashing?Pressure |
0.15MPa |
Air?Washing?Volume |
0.1-0.15N m3/m2 .hr |
Air?Washing?Pressure |
≤ 0.1MPa |
Maximum?Working?Temperature |
45C |
PH?Range |
Working: 4-10; Washing: 2-12 |
Operating?Mode |
Cross?Flow?or Dead End |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused?by large particles in raw water.
Turbidity |
≤ 25NTU |
Oil?&?Grease |
≤?2mg/L |
SS |
≤ 20mg/L |
Total?Iron |
≤?1mg/L |
Continuous?Residual?Chlorine |
≤?5ppm |
COD |
Suggested?≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Backwashing?Flow?Rate |
100-150L/m2.hr |
Backwashing?Frequency |
Every?30-60min. |
Backwashing?Duration |
30-60s |
CEB?Frequency |
0-4?times per day |
CEB?Duration |
5-10min. |
CIP?Frequency |
Every 1-3 months |
Washing?Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic?Pollution?Washing |
0.2%?Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic?Pollution?Washing |
1-2% Citric?Acid/0.2% Hydrochloric?Acid |
Component Material
Component |
Material |
Membrane |
Modified?PVDF |
Sealing |
Epoxy?Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
We are ready to share our knowledge of marketing worldwide and recommend you suitable products at competitive prices. So Profi Tools offer you value of money and we are ready to develop together with
Factory supplied Membrane Filtration Wastewater Treatment -
UF Membrane Module 9 inch PVDF Ultrafiltration Membrane Module UFf2880 Replacing Project – Bangmo , The product will supply to all over the world, such as: Algeria
, Victoria
, United States
, Each year, many of our customers would visit our company and achieve great business advancements working with us. We sincerely welcome you to visit us at any time and together we will prevail to a greater success in the hair industry.